Understanding the technique
Pulsed eddy current uses an electromagnetic transient response to screen for wall loss through suitable non-conductive insulation and weather protection. It helps focus insulation removal and detailed inspection.
Where it adds value
Insulated pipes, vessels and structures susceptible to corrosion under insulation.
The purpose is to provide evidence that supports a defined asset decision: prioritizing maintenance, investigating degradation, assessing serviceability or documenting equipment condition. The examination is planned around the asset's operating context and the information needed by the owner.
Inspection outputs
Screening maps and areas prioritized for detailed examination or insulation removal.
Planning considerations
PEC gives an averaged response over a probe footprint. Material, insulation thickness and nearby features influence results; local pitting may require other methods.
From scope to decision
Provide equipment identification, drawings, material details, operating conditions and previous inspection records where available.
Confirm the inspection objective, accessible locations, coverage, acceptance basis, site arrangements and reporting requirements.
Review recorded findings against the agreed scope, identify any coverage limitations and define the need for further inspection or engineering assessment.
Project questions
What information helps define a quotation?
Share the asset type, location, quantity, inspection objective and desired schedule. Drawings, previous reports and access information help the team prepare a realistic scope.
Can this technique be combined with other services?
Yes. Complementary examination or engineering assessment may be needed to characterize relevant findings. The combination depends on damage mechanisms, material, geometry and the decision required.